Derate bundled wires because there are more than three conductors in the conduit.
Conduit min 10 from roofdesk in attic.
This article describes recessed light downlight pot light clearance distances or spacing from insulation or wood or other combustibles in building ceilings other indoor spaces or outdoors in roofs soffits porches.
The most common type of electrical conduit for house wiring is the thin wall type.
I was also under the impression that if wiring is in an attic space that it may need to be derated because it can get very hot up there.
Emt electrical metallic tubing thin wall metal conduit.
Lengths with 5 ft.
A favorite target of electrical inspectors is the improper use of non metallic cable nm in exposed locations such as basement foundation walls or along the face of studs and joists in unfinished framed spaces.
The national electrical code which is the basis for all local building codes has specific regulations for installing electrical wires so that they are protected from damage.
Air leakage code requirements for recessed lights downlights.
Thin wall conduit is too thin for threaded joints.
Wiring methods shall not be installed within 25 cm 10 in of roof decking or sheathing except where directly below the roof surface covered by pv modules and associated equipment.
Whenever i do attic wiring i remove the insulation and staple it to the ceiling joist.
10 in below roof decking.
If this meets code then i will be running attic wiring in this manner from now on.
Derate the wires for ambient temperature because the attic temperature rises above 30 c.
Snap the cover onto the chase to conceal and protect the lines and cable.
A conduit carrying six tw type 12 gauge wires travels through an attic that reaches 110 degrees f 43 c in the summertime.
I m building a new home outside the city limits in liberty county in texas my electrician ran the main power feed wire from the meter through the exterior wall up into the attic and down into the breaker panel without any conduit.
Run weather tight conduit from an outdoor electrical box to the condenser unit.
Rigid conduit is sold mostly in 10 ft.
Lengths available usually for the larger diameter sizes.
Circuits shall be run perpendicular to the roof pen etration point to supports a minimum of 25 cm.