3 4 is sufficient for up to 20 tons according to the imc unless the drain outlet size is larger than 3 4.
Condensate drain pipe size calculation.
Air change rate calculator air mixing condensate generated cooling load sanity check duct size calculator exhaust hood cfm fluid mixing calculator psychrometric calculations vapor pressure deficit vpd window u shgc values default general calculators.
First calculate the mixed air condition.
Drain lines containing no flash steam.
If value of 0 entered calculator assumes proper diameter for discharge pipe velocity of 10 ft sec or less and includes a safety margin of 10 psig.
Online calculator to quickly determine condensate recovery pipe sizing for condensate recovery line by pressure loss.
A particular pipe size on a given grade will only carry a certain amount of water.
Ipc chapter 8 table 8 2 minimum condensate pipe size shows the equipment capacity in tons or kw and the minimum pipe size you can use.
Includes 53 different calculations.
Checks the capacity of drain tile on existing drainage systems.
Upvote 3 downvote 0 reply 1.
A rule of thumb the condensate load used to design condensate pipe lines should be twice the maximum production load.
Pump flow rate is less than 0 5 gallons min gpm.
Interesting question i don t know that i ve ever calculated it.
Lines consisting of two phase flow such as trap discharge lines which are selected according to the pressures either side of the trap.
The condensate pipe sizing chart figure 14 3 5 can be used to size any type of condensate line including.
The steeper the grade of the installed pipe the more water it will carry.
Per code condensate drain lines must be tied into the sanitary drain system by means of an indirect waste connection.
We usually size condensate drain based on nominal tonnage.
If value not known use pipe friction calculator to determine resistence of piping in feet of head.
The prinsco drainage calculator estimates the capacity of tile drainage systems.
When sizing condensate return lines in steam distribution system remember that the maximum condensate flow is achieved during plant start up when pipes and equipment are heated up.
Also you should be able to calculate the amount of moisture being condensed and then size the pipe based on sanitary pipe sizing per code.
Where cities allow drywells they work fine.
Equations displayed for easy reference.
The chart figure 14 3 5.
Bilinear interpolation break even calculator linear interpolation present future value.
2 tons 5 tons 1 30 tons 1 50 tons 1 175 tons 2 etc.
The condensate pipe siz ing chart.